Sydney IVF Spermient (K-SISP) - In vitro fertilization culture medium kit Australia - English - Department of Health (Therapeutic Goods Administration)

sydney ivf spermient (k-sisp) - in vitro fertilization culture medium kit

william a cook australia pty ltd - 42850 - in vitro fertilization culture medium kit - sydney ivf spermient is used to separate sperm by density, using density gradient solutions and centrifugation. it removes dead sperm, blood and somatic cells from healthy motile sperm. it is a 100% stock solution which can be diluted with sydney ivf sperm buffer to the required density. sydney ivf spermient is used to separate sperm based on density, using density gradient solutions.

Test Tube Heater Australia - English - Department of Health (Therapeutic Goods Administration)

test tube heater

william a cook australia pty ltd - 46944 - test tube heater - the test tube heater is intended to hold test tubes containing aspirated follicular fluid at a specified temperature.

Zenith Branch Endovascular Graft - Iliac Bifurcation - Graft, vascular, synthetic Australia - English - Department of Health (Therapeutic Goods Administration)

zenith branch endovascular graft - iliac bifurcation - graft, vascular, synthetic

william a cook australia pty ltd - 35281 - graft, vascular, synthetic - a one-piece graft which has three connected lumens to connect to the common iliac sidebranch and external iliac segments. the graft is manufactured from polyester, and in the common iliac and external iliac sections, is sewn to stainless steel self-expanding z stents. the internal iliac side branch has two reinforcing rings and a contracting nitinol stent. the graft is presented pre-loaded onto a delivery system for percutaneous delivery. the zenith branch endovascular graft ? iliac bifurcation is intended for the endovascular treatment of patients with aorto-iliac or iliac aneurysm, an insufficient distal sealing site within the common iliac artery and having morphology suitable for endovascular repair.

Zenith Fenestrated AAA Endovascular Graft - Graft, vascular, synthetic Australia - English - Department of Health (Therapeutic Goods Administration)

zenith fenestrated aaa endovascular graft - graft, vascular, synthetic

william a cook australia pty ltd - 35281 - graft, vascular, synthetic - this modular system self-expands stainless steel stents with braided polyester and monofilament polypropylene suture. each individual device has its own separate delivery system. the bare suprarenal stent of the proximal body graft contains barbs for additional fixation. the scallops and fenestrations is to allow the proximal margin to sit higher and allow uninterrupted blood flow to branch vessels of the aorta. radiopaque markers on the graft are to facilitate fluoroscopic visualisation. the zenith fenestrated aaa endovascular graft is indicated for the treatment of infrarenal abdominal aortic aneurysms (aaas) in high-risk patients who are not suitable for conventional open surgical repair or who are not suitable for repair with a standard zenith endovascular graft, when the aneurysmal disease extends up to the level of the renal arteries.

Zenith Universal Distal Body Endovascular Graft - Graft, vascular, synthetic Australia - English - Department of Health (Therapeutic Goods Administration)

zenith universal distal body endovascular graft - graft, vascular, synthetic

william a cook australia pty ltd - 35281 - graft, vascular, synthetic - the zenith universal distal body implant is a bifurcated endovascular graft with one long ipsilateral iliac limb and one short contralateral iliac limb. it is intended to work as a modular system in combination with other zenith proximal devices and iliac leg grafts. the graft is shipped loaded onto the h&l-b one-shot introduction system. it has a sequential deployment method with built-in features to provide continuous control of the graft throughout the deployment procedure. the zenith universal distal body endovascular graft is indicated for the endovascular treatment of patients with abdominal or thoracoabdominal aortic aneurysms, when used with the appropriate zenith proximal device and zenith iliac leg grafts. the patient must have anatomy suitable for endovascular repair, including: ? adequate femoral/iliac access compatible with the required delivery systems; ? an appropriate length of abdominal aorta, distal from the most proximal point of the overlap with the proximal piece to the aortic bifurcation.

Needle, aspirating, oocyte, single-use Australia - English - Department of Health (Therapeutic Goods Administration)

needle, aspirating, oocyte, single-use

william a cook australia pty ltd - 45676 - needle, aspirating, oocyte, single-use - intended to simultaneously or independently aspirate and flush follicles to harvest oocytes.

Graft, vascular, synthetic Australia - English - Department of Health (Therapeutic Goods Administration)

graft, vascular, synthetic

william a cook australia pty ltd - 35281 - graft, vascular, synthetic - the zenith fenestrated aaa endovascular graft with the h&l-b one-shot introduction system is indicated for the endovascular treatment of patients with abdominal aortic or aorto-iliac aneurysms having morphology suitable for endovascular repair, including: ? adequate iliac/femoral access compatible with the required introduction systems, ? non-aneurysmal infrarenal aortic segment (neck) proximal to the aneurysm: ? with a length that is at least 4 mm and unsuitable for a nonfenestrated graft, ? with a diameter measured outer wall to outer wall of no greater than 31 mm and no less than 19 mm, ? with an angle less than 45 degrees relative to the long axis of the aneurysm, and ? with an angle less than 45 degrees relative to the axis of the suprarenal aorta. ? ipsilateral iliac artery distal fixation site greater than 30 mm in length and 9-21 mm in diameter (measured outer wall to outer wall). ? contralateral iliac artery distal fixation site greater than 30 mm in length and 7-21 mm in diameter (measured outer wall to outer wall).

Tubing, vaccuum, single-use Australia - English - Department of Health (Therapeutic Goods Administration)

tubing, vaccuum, single-use

william a cook australia pty ltd - 46721 - tubing, vaccuum, single-use - used to connect ovum aspiration needles to a vacuum pump.

Graft, vascular, synthetic Australia - English - Department of Health (Therapeutic Goods Administration)

graft, vascular, synthetic

william a cook australia pty ltd - 35281 - graft, vascular, synthetic - the zenith universal distal body endovascular graft is indicated for the endovascular treatment of patients with abdominal or thoracoabdominal aortic aneurysms, when used with the appropriate zenith proximal device and zenith iliac leg grafts. the patient must have anatomy suitable for endovascular repair, including: ? adequate femoral/iliac access compatible with the required delivery systems; ? an appropriate length of abdominal aorta, distal from the most proximal point of the overlap with the proximal piece to the aortic bifurcation.

Graft, vascular, synthetic Australia - English - Department of Health (Therapeutic Goods Administration)

graft, vascular, synthetic

william a cook australia pty ltd - 35281 - graft, vascular, synthetic - the zenith branch endovascular graft-iliac bifurcation with the h&l-b one-shot introduction system is indicated for the endovascular treatment of patients with an aortoiliac or iliac aneurysm, an insufficient distal sealing site within the common iliac artery, and having morphology suitable for endovascular repair,including: ? adequate iliac/femoral access compatible with a 20 french (7.7 mm o.d.) introduction system, ? non-aneurysmal external iliac artery fixation segment distal to the aneurysm: ? with a length of at least 20 mm, ? with a diameter measured outer wall to outer wall of no greater than 11 mm and no less than 8 mm. ? non-aneurysmal internal iliac artery segment distal to the aneurysm: ? with a length of at least 10 mm (with 20-30 mm being preferred) ? with a diameter acceptable for proper sealing.